                              Motor Control PWM Example Program
===============================================================================================
Copyright(C) Redpine Signals 2016
All rights reserved by Redpine Signals.

This program should be used on your own responsibility.
Redpine Signals assumes no responsibility for any losses
incurred by customers or third parties arising from the use of this file. 
                                                  
Function description:
===============================================================================================
This example, uses the MCPWM driver to create 2 independent PWMs (running at the same frequency).
Square wave will be generated on channel 0 output PWM_1L and channel 1 output PWM_2L with the duty cycle 
goes from 0% to 100% in steps of 0.5% every 20 Milliseconds and goes down to 0% in the same step.  
===============================================================================================
Environment
===============================================================================================
Test Board:
---------------------
Smart EVK 

---------------------


Assistance software:
---------------------
None

===============================================================================================
Usage Procedure:
===============================================================================================

setup requirements 
------------------
Observe PWM 1L output on GPIO_19(J1.37) and PWM 2L output on GPIO_11(J1.19)
compile and run the application 
Note : GPIO_19 is not coming out of QMS/Q7 package 
===============================================================================================
Pass criteria:
===============================================================================================
Connect the external Tri LED to the PWM 1L and 2L outputs ,if LEDs brightness goes from 0% to 100% in steps of 0.5% every 20 
Milliseconds and goes down to 0% in the same step then the test is success .
===============================================================================================